// Language switcher on every page: EN default navI18n unless a locale // page supplied its own. Non-translatable paths link the menu to each homepage. const navI18n = options.navI18n || (() => { const L = uiFor('en'); const m = (options.seoHeadTags || '').match(/rel="canonical" href="([^"]+)"/); const path = m ? m[1].replace(/^https?://[^/]+/, '') : '/'; const translatable = TRANSLATED_PATHS.some(re => re.test(path)); const entries = [{ code: 'en', host: 'hengxang.com', name: 'English' }, ...LOCALES]; return { t: L, currentName: 'English', path, langItems: entries.filter(e => e.code !== 'en') .map(e => '
  • ' + e.name + '
  • ').join(''), }; })();

    Fiber Patch Cord Manufacturer

    HENGXANG assembles and tests fiber patch cords, pigtails and MPO/MTP harnesses in Yiwu, Zhejiang - the same factory that builds our outdoor cable since December 2000. We terminate LC, SC, FC, ST, MU, E2000 and MPO/MTP connectors onto G.652D, G.657A1/A2 and OM1-OM5 fiber, with 100% insertion loss and return loss testing on every piece.

    Buyers choose this fiber patch cord manufacturer for three reasons: assembly and polishing under one roof, test data with every cable, and an MOQ of 100 pieces that lets project teams buy to the bill of materials instead of the container. Standard orders ship in 3-6 days; MPO trunk and fanout harnesses in 6-10 days.

    This page lists every cord family we build with MOQ and lead time, the quality numbers we test to, our OEM/ODM service, certifications, factory facts, and the answers buyers ask before signing. One page, the whole supplier story. Send your BOM and the export desk replies with a quote within 24 hours on business days.

    Who buys here: network installers quoting FTTH projects, data center teams fitting out halls, ISPs stocking closures and frames, and distributors building private-label lines. Each gets the same treatment - a written quote with test data, a named contact, and cords that read right on the meter the day they arrive.

    Strona główna / Produkty / Fiber Patch Cord & Pigtail

    Fiber Patch Cord & Pigtail Products

    What We Build: Specs, MOQ and Lead Time by Family

    Three numbers decide most purchase orders: what you can order, how many, and how fast it lands. The table lists every patch cord family this fiber patch cord manufacturer assembles in its own workshop. Lead time counts from deposit and includes 100% testing and packing.

    Cord familyBuildLengthMOQLead time
    Simplex / duplex single-mode (LC, SC, FC, ST)G.652D / G.657A1, UPC or APC, 0.9-3.0 mm, PVC or LSZH0.3-30 m100 pcs3-6 days
    Multimode duplex (OM1-OM5)50/125 and 62.5/125, aqua / lime / orange jackets0.3-30 m100 pcs3-6 days
    Pigtails 0.9 mmSC, LC, FC, ST - UPC or APC, single-mode0.5-2 m200 pcs3-5 days
    MPO / MTP trunk cable8-72 fibers, OS2 / OM3 / OM4, polarity A, B or C, male / female0.5-30 m20 pcs6-10 days
    MPO-LC / MPO-SC fanout harnessCassette-ready 0.9 mm legs, 8-24 fibers0.35-5 m20 pcs6-10 days
    Armored patch cordsSpiral steel armor, LSZH jacket, LC-LC and mixed types0.5-10 m100 pcs4-7 days
    FTTH jumpers1.6-2.0 mm drop-style, SC/APC and mixed heads1-5 m200 pcs4-6 days
    Outdoor duplex branch cableMDPE jacket, pre-made long runs to 100 m10-100 m100 pcs5-8 days

    MOQ and lead-time figures are standard production windows; peak season around Chinese New Year can add 5-7 days. Fixed delivery dates are confirmed in writing on the proforma invoice.

    What buyers order most from this shelf

    These five SKUs cover most purchase orders we ship. Your mix may differ - the full shelf sits in the product grid above, and everything on it builds to your length and label.

    Cords can arrive pre-loaded into termination boxes, cassettes or ODF panels - factory-loaded panels cut on-site assembly to plug and label. For the raw cable behind every cord, see our fiber optic cable range, all drawn from the same plant.

    UPC or APC? Pick the Polish by the Link, Not by Habit

    The polish decides the return loss, and the return loss decides whether a link runs clean. Here is how this fiber patch cord manufacturer guides the choice:

    UPCAPC
    Polish angleNear 0 degrees8 degrees
    Connector colorBlueGreen
    Return loss (single-mode)≥50 dB≥60 dB
    Best forLAN, data center port counts, general patchingFTTH/RF-over-glass, DWDM, long-haul and high-gain links
    RuleNever mate UPC into APC - the angle mismatch damages both ferrules and spikes the loss

    FTTH builds in Asia and the Middle East run SC/APC at the ONT almost everywhere; data centers stay UPC on OM4 and OS2 patching. When one site mixes both, we color-split the labels so installers never grab the wrong bag. Tell us the equipment side - we flag conflicts before you order.

    MPO Polarity A, B and C: Getting It Right the First Time

    MPO links fail on polarity more than on loss. The fibers inside a 12-fiber trunk must line up transmit-to-receive at both ends, and three standards describe how:

    Send us the cassette model and the port plan - a photo of the panel is enough. We build and label the trunks to your method, male or female pins, and state the polarity on every label. MPO assembly runs in a separate cell with its own interference and geometry checks, so a 72-fiber trunk carries the same paperwork as a simplex cord.

    Uniboot and High-Density Options for Packed Racks

    When a 1U panel holds 48 ports, cable bulk becomes the enemy. Our high-density options cut the clutter:

    These options are OEM territory: send the rack elevation, and this fiber patch cord manufacturer returns a length schedule with the quoted set.

    Quality You Can Read From the Data Sheet

    A patch cord is a test result, not a product photo. These are the numbers we build and test to, batch after batch:

    Failure rates on standard cords run well under 0.1% in our shipment records (draft figure - confirm with sales). When a cord is good, the label proves it; when a claim happens, the same label settles it.

    Pigtail or Patch Cord? Match the Product to the Joint

    Both start as the same fiber - the difference is one connector versus two, and it changes how your crew works:

    Pigtail (one connector)Patch cord (two connectors)
    Where it goesSpliced onto cable ends, inside closures, boxes and ODFsPlugged between panels, ONTs and equipment ports
    Cable style0.9 mm buffered fiber1.6-3.0 mm jacketed zip or simplex
    Field skill neededFusion splicer and a trained jointerNone - plug and label
    Best economicsHigh-count terminations (48+ ports per frame)Moves, adds and changes; equipment patching

    Most networks use both: pigtails at the frame, patch cords between frames. Ordering both from one fiber patch cord manufacturer keeps the connector geometry consistent, so a pigtail spliced today mates with a cord bought next year at the same loss.

    How to Read Our Test Labels and Batch Files

    The label is the warranty. Every cord from this fiber patch cord manufacturer carries a label with the connector types, fiber grade, length, and the measured IL and RL values from its own bench pass. Batch files follow the same fields so your QA team can sort and audit:

    Procurement teams tell us the test file shortens acceptance meetings to minutes: the installer plugs in, the meter matches the label, the batch signs off.

    Connector and Naming Decoder for Buyers

    Procurement teams read datasheets faster with this decoder - it covers every code on our quotation sheets:

    CodeMeaningWhere you see it
    LCSmall form factor latch connector, 1.25 mm ferruleData centers, SFP ports
    SCPush-pull square connector, 2.5 mm ferruleFTTH ONTs, media converters
    FCScrew-on metal connectorTest gear, older telecom racks
    STBayonet metal connectorLegacy campus backbones
    MU / E2000Compact and shielded-ferrule typesDense panels, European telecom
    MPO / MTPMulti-fiber push-pull, 8-72 fibers40/100G links, MDC cassettes
    UPC / APCUltra / angled physical contact polish - blue / greenJacket and connector colors
    OS2 / OM1-OM5Single-mode and multimode fiber gradesJacket colors: yellow, aqua, lime, orange
    Simplex / duplex / unibootSingle strand, zip-cord pair, round leg with pull-tabHigh-density rack builds

    Send a drawing with any code you do not see here - our workshop builds hybrid and special heads, such as transceiver-side conversions and mode-conditioning cords, on request.

    OEM, ODM and Private-Label Capability

    As an OEM fiber patch cord manufacturer we build to your drawing, your colors and your label. Three service levels cover most buyers:

    OEM projects we shipped (draft references - replace with your approved cases)

    “Every bag carried a test label that matched our asset system. Zero re-terminations across the whole fit-out.” - project manager, European data center contractor (draft testimonial - replace with your approved reference).

    “They held the color and length spec across six batches, and the MPO polarity was right the first time.” - purchasing lead, US fiber installer (draft testimonial - replace with your approved reference).

    Patching into splitters or WDM points? Buyers commonly pair cords with our PLC splitters, adapters and fast connectors in the same container, so one purchase order covers the whole rack.

    Wholesale and Distributor Program

    Distributors live on stock turn and clean paperwork. The wholesale program at this fiber patch cord manufacturer runs on five rules:

    New distributors start with a trial mixed order and scale to frame terms once the return rate proves itself - most stay on call-off terms within two cycles.

    Warranty, After-Sales and How Claims Settle

    After-sales is where trading companies go quiet and factories stay answerable. Our policy runs on three commitments:

    Retained samples from every batch stay on the shelf for the warranty period, so a dispute never turns into opinion versus opinion. It is one reason repeat buyers treat this fiber patch cord manufacturer as a long-term extension of their own warehouse.

    Certifications and Test Compliance

    Every cord inherits the factory's quality system. The plant runs under ISO 9001:2015, our CE paperwork covers the connector families sold into the EU, and our R&D director holds the utility patent on a fiber optic quick connector. The documents are public on the certificate page.

    CertificateRelevance to your cords
    ISO 9001:2015Quality management for assembly, test and shipment of optical products
    OHSAS 18001:2007Occupational health and safety management
    CE reportsConnector families shipped into the EU
    Utility model patentFiber optic quick connector, inventor Zhou Liubo - the same bench team assembles your cords

    Compliance references: connector optical performance measured per IEC 61300 test sequences, end-face cleanliness to IEC 61300-3-35, and RoHS-compliant jacket materials on request. Certificate copies ride with every quotation.

    Factory Strength: The Workshop Behind the Label

    Cords are only as good as the bench that tested them. Our assembly workshop sits inside the same Yiwu compound where we extrude cable - 25 years of fiber work under founder LING LI, started December 2000:

    Because assembly, cable extrusion and packing share one compound, a mixed order of cords plus bulk cable leaves on one truck to Ningbo or Shanghai port.

    Company quick facts
    FoundedDecember 2000, Yiwu City, Zhejiang, China
    FounderLING LI, Founder & General Manager
    FocusFiber patch cords, pigtails, MPO/MTP harnesses, cable, connectors, splitters, ODFs
    Export markets40+ countries across Asia, the Middle East, Africa, Europe and the Americas
    Response timeQuotes within 24 hours on business days

    Why Buyers Pick HENGXANG Over Other Suppliers

    Compare suppliers on the points that decide project outcomes, not brochure adjectives:

    FactorHENGXANGTypical trading company
    Testing100% IL/RL, reading on each labelBatch sampling, no per-cord data
    MOQ20-200 pcs by family; trial lots welcome1,000 pcs minimums per type
    Connector rangeLC, SC, FC, ST, MU, E2000, MPO/MTP in one order2-3 common types only
    Quote speedWithin 24 hours on business daysDays, forwarded to a third factory
    Mixed ordersCords + cable + splitters + ODFs, one containerSingle category
    TraceabilityBatch label + per-cord test reading + fiber lotBox label only
    Factory accessLive video audits and third-party inspection welcomeRarely allowed

    And one habit that wins tenders: we quote what your rack actually needs. If a duplex cord should be uniboot for a packed patch panel, the quote says so before you order the wrong build.

    How We Work With You: From BOM to Delivered Cartons

    Six steps, all in writing, one contact:

    Between orders, the same desk answers technical questions - and our FAQ page covers the common ones in plain language.

    Worked Example: A 2,000-Piece Mixed Order, Start to Seal

    Numbers beat adjectives. Here is a typical mixed project (illustrative figures - your quote states yours): 1,200 LC-LC duplex single-mode cords at 3 m, 500 SC/APC pigtails, and 300 MPO-12 OM4 trunks at 5 m for one data hall:

    StepDetail
    Day 0BOM received by WhatsApp; quote issued next morning with tier pricing
    Day 1-2Samples pulled from stock and airfreighted for approval
    Day 3-8Assembly: pigtails first, then cords, then MPO trunks; labels printed to the buyer's asset code format
    Day 8-9100% IL/RL on all 2,000 pieces; test file exported to the buyer's format
    Day 10Carton pack: 40 cartons, desiccant, barcode labels; 14 cbm total - fits half a 20 ft container
    Day 11Trucked to Ningbo, FOB; B/L and test file issued 2 days after sailing

    Eleven days from BOM to sealed cartons - that is the pace of a factory that assembles, tests and packs under one roof, and the reason buyers treat this fiber patch cord manufacturer as a stockroom extension rather than a vendor.

    Build the Whole Link, Not Just the Cords

    Cords land the signal, and the rest of the passive chain comes from the same plant: bulk cable for the routes, connector components for field assembly, adapters and termination boxes for the panels, splitters for the split points, and ODFs for the central office. New to ODF planning? Our ODF planning guide maps port counts to rack layouts in plain language. One supplier, one freight plan, one warranty conversation.

    Frequently Asked Questions

    What is your MOQ for fiber patch cord orders?

    Standard simplex and duplex cords start at 100 pieces per type, pigtails at 200 pieces, and MPO/MTP trunks at 20 pieces. First-time buyers can order below MOQ for a live trial project. As a flexible fiber patch cord manufacturer we also mix lengths, colors and connector types inside one production run.

    How fast can you deliver a patch cord order?

    Standard LC, SC, FC and ST cords ship in 3-6 days, pigtails in 3-5 days, and MPO/MTP trunks or fanouts in 6-10 days. Orders above 10,000 pieces run on a production plan we confirm in writing with the proforma invoice.

    Do your patch cords come with test reports?

    Yes. Every cord passes 100% insertion loss and return loss testing before packing. You receive the test data with the shipment - per cable or per batch label, in the format your QA team prefers. Claims never argue about data because every cord carries its own numbers.

    What is the difference between UPC and APC connectors?

    UPC ferrules are polished at a small angle and blue in color; APC ferrules are polished at 8 degrees and green. APC gives a higher return loss, which matters for RF-over-glass and long-haul links. Never mate a UPC plug into an APC adapter - the angled surfaces grind and damage both.

    Should I choose OM3, OM4 or OM5 multimode cable?

    OM3 supports 10G to 300 m and 40/100G to 100 m; OM4 extends 40/100G to 150 m in most designs; OM5 adds support for short-wavelength division multiplexing. For new data center builds we quote OM4 as standard and OM5 where the design calls for it. Both come in aqua and lime jackets to your spec.

    Can you make custom lengths, colors and private labels?

    Yes. Lengths run from 0.3 m to 30 m for standard cords and to 100 m for outdoor duplex builds. Jacket colors include yellow, aqua, lime, violet, orange and white, and boot colors are free to mix. Your logo goes on the cable label, the bag and the carton - OEM label printing is free above 500 pieces.

    How do you pack patch cords for shipping?

    Each cord ships in a PE bag with a data label showing type, length and test results. Bags pack into export cartons with desiccant, and drums are used for outdoor builds above 20 m. Carton size and labels follow your instructions for direct-to-shelf distribution.

    What polarity options do you offer for MPO trunks?

    We build Method A, Method B and Method C polarity to your network drawing, in male and female pins, and UPC or APC polish. Tell us the cassette and port layout, and we confirm the polarity in the quotation so your panels line up end to end.

    Which fiber and ferrule grades do you use?

    Single-mode cords use G.652D or G.657A1/A2 fiber, multimode uses OM1 through OM5, and every ferrule is zirconia ceramic. Ferrule lots pass 3D interferometer checks on sampling, and finished cords face 100% IL and RL testing on the bench.

    What happens if a cord fails in the field?

    Send us the batch label and the test reading. Confirmed factory faults are replaced in the next production run at no cost, and the claim settles on data rather than opinions. Failure rates on standard cords run well under 0.1% in our shipment records (draft figure - confirm with sales).

    Get Your Fiber Patch Cord Quote Today

    Send your BOM - connector types, fiber grades, lengths, quantities. Your quote with prices, MOQ, lead time and packing plan arrives within 24 hours on business days. Free samples for project evaluation.

    Request a Quote Now

    WhatsApp: +86 134 3434 9304  |  Email: peter@hengxang.com

    Contact By Whatsapp